สารต้านมะเร็งจากพืชสมุนไพร ซินโครตรอนยืนยัน สารต้านมะเร็งจากพืชสมุนไพร electro-magnetic radiation created in a synchrotron, presentation on a specific application of synchrotron radiation.
เทคนิคจุลทรรศน์อินฟราเรด (FTIR microspectroscopy)
Micro-IR Our skin emits infrared light, which is why we can be seen in the dark by someone using night vision goggles. In space, IR light maps the dust between stars.
การใช้แสงอินฟราเรดวิเคราะห์สิ่งมีชีวิต A motion of diatomic molecules as a spring Stretching vibrations absorbance 500 1000 1500 2000 2500 3000 3500 4000 Wavenumbers (cm-1) c c H H H H Bending vibrations 1 O H N C HIGH LOW 4000 2500 2000 1800 1600 1550 650 Wavenumber(cm-1) = H H H H wavelength (cm) How does IR detect biologcal sample? Because this sample contain biochemical molecule, which contain various function group. Each chemical bond in a molecule will absorb IR energy, then vibrates at a frequency which is characteristic of that bond. A group of atoms in a molecule (e.g. CH2) may have multiple modes of oscillation caused by the stretching and bending motions of the group as a whole. If an oscillation leads to a change in dipole in the molecule, then it will absorb a photon which has the same frequency. In chemical analysis, IR spectrum will show as wave number which correlate to wave length c c
อินฟราเรดสเปกตรัม C C H H H H 1650 cm-1 (N–H) bending (C=O) stretching Biomedical samples comprise a mixture of proteins, nucleic acids, lipids and carbohydrates, and this complexity is reflected in the IR absorption spectra they produce. The amide I band at around 1650 cm-1 which results principally from the (C=O) stretching vibrations of protein amide bonds; The amide II band close to 1549 cm-1 resulting from a combination of the (N–H) bending and (C–N) stretching vibrations of the amide bonds; the (C=O) stretching of lipids at about 1740 cm-1; and the antisymmetric nas(PO2) stretching of nucleic acids and phospholipids near 1225 cm1. Many biological samples have highly specific vibrational signatures that form a database for discriminating various states
โครงสร้างทุติยภูมิของโปรตีน random coil - helix - sheet This amide I band composes of 80% from the C=O stretching vibration of the amide group, coupled to the in-plan N-H bending and C-N stretching amide I band consists of a series of overlapped component bands which occurs as a result of the secondary structures present in proteins.
ติดตามการเปลี่ยนแปลงระดับเซลล์ (ไมโครเมตร) ใช้เทคนิคจุลทรรศน์อินฟราเรด ? ติดตามการเปลี่ยนแปลงระดับเซลล์ (ไมโครเมตร) พิสูจน์เอกลักษณ์ ศึกษากลไกการเปลี่ยนแปลงต่าง ๆ
ข้อมูลอินฟราเรดสเปคตรัมของเซลล์มะเร็งเม็ดเลือดขาว (U937) ที่ ผ่านการบำบัดด้วยสารสกัดจากสนสามสนใบ ติ้วขน และยาเมลฟาแลน โปรตีน ไขมัน
ข้อดี: เทคนิคจุลทรรศน์อินฟราเรด ขั้นตอนการเตรียมตัวอย่างที่ไม่ยุ่งยาก ไม่จำเป็นต้องใช้สารเคมีใด ๆ ในการเตรียมตัวอย่าง ใช้เวลาในการตรวจวิเคราะห์สั้น ลดค่าใช้จ่ายจากการใช้สารเคมีราคาสูง
Questions are welcome.